CAP600 Series & CAP1200 Series Central Air Purifiers — The
Ultimate in Whole House Air Purification
True
HEPA Filtration With Optional Germicidal UV-C Lamps
When it comes to harmful air pollutants, what you can’t see can
hurt you. CAP600 series and CAP1200 series Central Air Purifiers with
true HEPA filtration are often recommended by allergists, pediatricians
and other healthcare professionals for patients with allergies, asthma
and other respiratory problems. CAP600 & CAP1200 series models represent
the ultimate in home air purification systems that deliver clean, pure
healthy air into your customers’ homes.
All CAP600 series and CAP1200 series models feature a HEPA filter that
is tested and certified to an efficiency of 99.97% or higher at 0.3 microns.
This HEPA filter is similar to the kind used to cleanse the air in hospital
operating room suites. Your customers can also add-on an optional UV-C
or UV Plus lamp for enhanced control of microbes, VOCs and odors.
"Because of its high efficiency at filtering out tiny particulates,
HEPA filtration is recommended for those individuals who suffer
from allergies, asthma or other respiratory problems..."
–American Lung Association |
Abatement HEPA Filter Captures Microscopic Contaminants
No other filter captures microscopic contaminants as effectively as
a true HEPA (High Efficiency Particulate Air) filter. Scientific studies
have shown that more than 99 out of every 100 particles in indoor air
are smaller than one micron in size–far too small to be captured
by most upgraded filters let alone low-efficiency throwaway furnace filters.
The HEPA filter used in the CAP600 series and CAP1200 series models are
tested and certified to capture at least 99.97% of particles 0.3 microns
in size.
Internal Motorized Impeller Circulates Air
CAP600 series and CAP1200 series Central Air Purifiers are designed
to supply HEPA-filtered air to the entire conditioned space in the house
without adding any load to the HVAC motor & blower. A powerful, internal
motorized impeller pulls contaminated air out of the return, through the
filters and pushes the purified air back into the return plenum. A typical
installation can replace the entire volume of air in the home with purified
air up to 75 times per day.
Simple
Partial Bypass Installation
Installing CAP600 series and CAP1200 series units in a “partial
bypass” configuration further enables the units to pull air through
the highly-efficient filters without adding any appreciable load to the
HVAC motor & blower. Bypass connections are made by cutting a 10-inch
diameter hole into the return duct and connecting the inlet of the CAP
unit to the duct with 10-inch rigid or flexible ducting. The exhaust of
the CAP unit is similarly connected into the return duct or plenum downstream
from the inlet connection to complete the "bypass loop".
A HEPA Home is a Healthier Home
CAP600 series and CAP1200 series units are designed for use in both new
installations and for retrofit applications. CAP600 series models are
designed for use in one to four ton forced-air systems. CAP1200 series
models are designed for use in larger (four to ten ton) residential and
commercial systems. One CAP unit is required for each HVAC system and
installed by a licensed HVAC professional.
Standard CAP600 Model
The standard CAP600 model is equipped with three stages of filtration:
Stage One is an inexpensive Fiber-Trapper® filter
designed to capture up to five times more dirt and larger particles than
a standard throwaway 1” furnace filter. This filter is even washable
if the homeowner wants to reuse it.
Stage Two is a dual-purpose Vapor-Lock® carbon filter
that captures smaller particles, as well as odors and some volatile organic
compounds (VOCs).
Stage Three is a HEPA filter designed to capture bacterial,
mold and fungal spores, pollens and other lung-damaging microscopic particles.
“Of primary concern from a health standpoint are small,
invisible respirable-size particles, with a higher probability of
penetrating deep into the lungs…. And may cause chronic health
effects.”
– US EPA Study |
CAP600-UV and CAP600-UVP Models
These top-of-the-line models have all of the features of the standard
CAP600 model, plus the added benefits of our germicidal UV-C or UV Plus
lamp technology.
The CAP600-UV is equipped with an ozone-free, high-output germicidal
UV lamp designed to irradiate and kill bacteria, mold and fungal spores,
viruses and other microbes as they pass the lamp or are trapped on the
HEPA filter.
The CAP600-UVP model is equipped with a special dual-output lamp that
generates both germicidal UV and a controlled amount of trivalent oxygen
(ozone) via an oxidation reaction called photolysis. This lamp provides
enhanced effectiveness against odors caused by mold and fungal growth
or VOCs that may be present in the dark, damp recesses of the HVAC system.
When the filter access door is opened for inspection or servicing, both
models feature a safety interlock switch. The electrical interlock instantly
deactivates the lamp to protect against any possibility of direct skin
or eye exposure to UV light.
CAP1200-UV and CAP1200-UVP Models
Both models contain larger internal blower systems designed to handle
the filtration requirements of HVAC systems that are four tons (1,600
cfm) or larger, plus have the added benefits of UV-C or UV Plus lamp technology.
These units have four stages of filtration to handle the higher dirt-loading
requirements of larger systems:
Stage One is an inexpensive Fiber-Trapper® filter
designed to capture up to five times more dirt and larger particles than
a standard throwaway 1” furnace filter. This filter is even washable
if the homeowner wants to reuse it.
Stage Two is a 2" pleated particulate filter.
Stage Three is a dual-purpose Vapor-Lock® carbon
filter that captures smaller particles, as well as odors and some volatile
organic compounds (VOCs).
Stage Four is a HEPA filter designed to capture bacterial,
mold and fungal spores, pollens and other lung-damaging microscopic particles.
The CAP1200-UV is equipped with an ozone-free, high-output germicidal
UV lamp designed to irradiate and kill bacteria, mold and fungal spores,
viruses and other microbes as they pass the lamp or are trapped on the
HEPA filter.
The CAP1200-UVP model is equipped with a special dual-output lamp that
generates both germicidal UV and a controlled amount of trivalent oxygen
(ozone) via an oxidation reaction called photolysis. This lamp provides
enhanced effectiveness against odors caused by mold and fungal growth
or VOCs that may be present in the dark, damp recesses of the HVAC system.
When the filter access door is opened for inspection or servicing, both
models feature a safety interlock switch. The electrical interlock instantly
deactivates the lamp to protect against any possibility of direct skin
or eye exposure to UV light.
|